Jetting is typically caused by an abrupt change of section between the gate and the mold. Image from Mold Plastic Injection.
One of the leading causes of rejects of injection-molded parts is surface defects. These defects may be located at the gate or elsewhere in the part and deviate from the customer-established standard of acceptance.
You can also read: 3 Common Injection Molding Challenges and How to Solve Them
As with any other defect, recognizing and naming it properly is the first step. So here, we will address three typical surface defects in injection molding, their causes, and possible solutions.
Sink marks deform the surface of a part in areas with thick geometry. Uneven cooling of the material causes these deformations. Courtesy of Hawk Ridge Systems.
Sink marks arise from molecular movement within the part. They are typical of thick-walled areas in the product (beyond 6 mm) and are particularly visible when the part has different cross sections, alternating thick and thin walls.
These thick-walled areas remain hot for long periods, enabling molecular movement. Therefore, molecules have time and energy to arrange, organize, crystallize and “pull” the surface towards the inner section of the component.
Sink marks are more visible in semi-crystalline materials and in materials with low elastic modulus, where the rigidity of the wall is not enough to counteract the pulling forces of the molecular movement.
The most radical way to solve the problem is to follow the first commandment in the design of injection-molded parts: design parts with a constant cross-section and avoid material accumulation.
Another common defect in injection molding is called “jetting,” and it is associated with an abrupt change of cross-section between gate and mold. Here, the polymer enters the cavity through the gate but without any restriction. When the melt goes inside the mold and faces no wall ahead, it fills very much like toothpaste in a glass, describing the pattern of what some molders call “mouse tail.”
Jetting is typically caused by an abrupt section change between the gate and the mold—image from Mold Plastic Injection.
This defect is typical of a poorly designed gate. The mold should be designed to fill in a laminar way, in concentric circles.
Though some parameters can help, such as dramatically reducing injection velocity when the material fills the gate (I am talking about speeds of 1 to 5 mm/s), to be honest, I have only been able to solve the problem by redesigning the gate.
It is also possible to induce excessive shearing in the material at the gate, degrading the part. A degradation defect at the gate is normally recognized as a star-like pattern, where several lines start from the gate and propagate as beams. Normally, this defect also shows signs of yellowing in the pattern.
Splay marks may be associated with high shearing in the mold. Image from Sentera Plastics
This problem is normally associated with very narrow gating. For example, submarine or banana gates, which force the material to flow at high speed through very thin cross sections, can degrade the part.
As concerns over environmental and health risks grow, the aviation industry is taking crucial steps.…
New findings reveal microplastics in brain tissue, raising concerns about links to cognitive decline. Microplastic…
The world is bracing to adapt as the new administration reveals its hand. Changes in…
ANTEC® 2025 brings together scientists, engineers, and industry leaders to shape the future of plastics…
The past year marked significant growth for Bcomp, a leader in flax-based bio-composites, with achievements…
The global composites market is experiencing steady and significant growth. Market analysts expect that it…